Software/Programming
7.2 COPYING CONFIGURATION between DATAFLOW RTU Units: This note explains how to preserve
programmed default settings.
TO COPY CONFIGURATION FROM AN OLDER-FIRMWARE DATAFLOW RTU TO A NEWER-
FIRMWARE DATAFLOW RTU, while preserving the default settings of additional programmable
features:
7.2.1 Connect older-firmware unit to the serial cable and power supply.
7.2.2 From the Programmer Main Screen, press 2 to select DATAFLOW RTU configuration.
7.2.3 Press F3 to Upload.
7.2.4 Enter a filename in the File Name field.
7.2.5 Press F6 to write this configuration to the (named) file.
7.2.6 Disconnect the older-firmware unit from the serial cable and power supply.
7.2.7 Connect the newer-firmware unit to the serial cable and power supply
7.2.8 Press F3 to Upload from the new unit.
7.2.9 Enter the filename from Step 4 in the File Name field.
7.2.10 Press F5 to Read the (named) file.
7.2.11 Press F4 to download the configuration to the newer-firmware unit.
7.2.12 Press F10 to Return to the Programmer Main Screen.
7.3 TO COPY ALL INFORMATION from source-configuration DATAFLOW RTU to same-version target
DATAFLOW RTU:
7.3.1 Connect older-firmware unit to the serial cable and power supply.
7.3.2 From the Programmer Main Screen, press 2 to select DATAFLOW RTU configuration.
7.3.3 Press F3 to Upload.
7.3.4 Disconnect the source-configuration unit from the serial cable and power supply.
7.3.5 Connect the (same-version) target unit to the serial cable and power supply.
7.3.6 Press F4 to download the configuration to the target unit.
7.3.7 Press F10 to Return to the Programmer Main Screen.
8. APPLICATION EXAMPLES
8.1 The following examples provide demonstrations of OMEGA DATAFLOW RTU operation. All
examples are included and can be loaded as Software Programming configuration files on the
accompanying programming disk.
8.1.1 These are not stand alone examples. Examine and understand each example in sequence
before proceeding to the next. These illustrations and demonstrations have been designed to
run in a laboratory environment using dummy loads for antennas.
8.1.2 The frequency programmed into the configuration files is 460 MHz. If your RTU system does
not operate in this band, change the configuration file frequency to reflect a value you can use.
8.1.3 UPLOAD or DOWNLOAD commands that change RTU configuration also disable the
transmitter. Cycle the RTU by turning it OFF then ON to re-enable the transmitter and re-
establish normal RTU operation.
( B-14 )